Common array manager - Jan 1, 2023 · Common Array Manager alarm code xx.66.1040: A controller cache backup battery has failed. Refer to <Document 1021057.1> Sun Storage Common Array Manager (CAM): How to Verify Critical Faults for Sun Storage 2500, 2500-M2, 6000 and J4000 Arrays. Changes. No changes have occurred on the array, other than the automated Learn Cycle has been run. Cause

 
Sun Storage Common Array Manager (CAM): How to Upgrade Firmware for Sun Storage 2500, 2500-M2, 6000 Arrays, J4000 JBODs, and F5100 Flash Arrays. (Doc …. Bingewatch.com

1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Storage Common Array Manager 6.10. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1Sun StorageTek Array Administration Guide, Version 6.5.0. PDF. Sun StorageTek Common Array Manager User Guide for Open Systems. HTML. PDF. Sun StorageTek Common Array Manager CLI Guide, Version 6.5.0. HTML. PDF. Sun StorageTek Common Array Manager Software 6.5 Product Library Documentation.These Common Array Manager 6.0.1 Release Notes describe new features, known issues, patches and installation notes, and provide the most current product information. Sun StorageTek Common Array Manager Software Release Notes, Release 6.0.1 ...Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports.Sun Storage Common Array Manager. Quick Start Guide. 2. Download Sun Storage Common Array Manager Software and Patches. 1. Sign in to My Oracle Support: … Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.8.1. 2 2510_exmoor N1532-735843-002 nge/N1532-735843-002.dlp It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).It is best practice to upgrade HBAs (SG-XPCIE8SAS-E-Z) to Phase 14 firmware (1.26.03 or later) before upgrading JBOD installations to Sun Storage Common Array Manager version 6.6 and above. This helps avoid issues when discovering JBODs that have SIM firmware 3A53 (J4200) or 3R53 (J4400).9. Choose Typical to install the full management software on the data host. 10. Click next to display the Review Selections Screen. The screen should show that the software to be installed is the Full Install. The …“Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release NotesSun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options …This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training for Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. Sun StorageTek Common Array Manager 软件发行说明 3 发行文档 以下是 Sun StorageTek Common Array Manager 的相关文档列表。对于文件号码中带 有 nn 后缀的文档,请使用其最新版本。 此外,Common Array Manager 软件还包含有关 CLI 命令的联机帮助和手册页。 Sun Storage Common Array Manager (CAM) - Version 6.9 to 6.10 [Release 6.0] Information in this document applies to any platform. Symptoms. When attempting to launch Service Advisor from Sun Storage Common Array Manager (CAM), the following message appears: "Service advisor package not installed for this type of device."vi Sun StorageTek Common Array Manager Software Installation Guide • October 2006 Creating Initiators to Assign to Hosts 61 To Create An Initiator and Assign It To a Host: 61 Using the New Volume Wizard to Create and Map Volumes 62 To Use the New Volume Wizard to Create Volumes 62 About Volumes and the Default Domain or Partitioned …iv Sun StorageTek Common Array Manager CLI Guide • April 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 29 Examples 30Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note – Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.From Preferences > Advanced > Proxies (or a similar path, depending on your browser), add the Sun Storage Common Array Manager management host name to the “No Proxy for” section. Recent Firefox versions might require you to accept and add a security certificate prior to bringing up the authentication page.Hi! I have Sun StorageTek 2540 FC array and CAM works very slowly - I can wait for software response even more than 2 minutes... I run this software on Windows machine with Firefox Web Browser but spe | The UNIX and Linux ForumsApplying Solaris patch 147416-02 (sparc) or patch 147419-02 (x86) to Sun Storage Common Array Manager (CAM) version 6.9.0 may cause registered arrays to present an alarm stating that out-of-band (oob) communication has been lost, and report the health status of the array as "Lost Communication"To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software.Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays.Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays.Jun 4, 2023 · This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware ... Sun Storage 2530 Array - Version Not Applicable and later Sun Storage 6180 Array - Version All Versions and later Sun Storage 6580 Array - Version All Versions and later All Platforms Goal. This document reviews the procedures for collecting performance statistics from arrays that can be managed using Sun Storage Common …Sun Storage Common Array Manager. Quick Start Guide. 2. Download Sun Storage Common Array Manager Software and Patches. 1. Sign in to My Oracle Support: …These release notes cover the software released on the Sun StorageTek Common Array Manager Software 6.0.0 CD. The Release Notes consist of the following sections: Features in This ReleaseGoal. This article documents Sun Storage 2540-M2 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. …Jun 4, 2023 · This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware ... Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports.This document describes a possible problem in Sun Storage Common Array Manager (CAM) version 6.9.0.20 on Solaris that can prevent registration of arrays. CAM 6.9.0.20 involves the installation of CAM 6.9 and then the addition of either <Patch 147416-02> (Solaris SPARC) or <Patch 147419-02> (Solaris x86). Array registration in … 1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user to root: $ su - Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays.The Sun Storage Common Array Manager CLI Guide, Version 6.9.0, describes the commands in the sscs command-line interface (CLI) for Oracle's storage arrays. Review the latest array baseline firmware versions delivered with Oracle's Sun Storage Common …Mar 24, 2021 · Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS) Storage Lifecycle Manager(SLM) In Band Proxy for RAID devices The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. xii Sun StorageTek Common Array Manager Software Installation Guide • January 2007 How This Book Is Organized Chapter 1 provides an overview of the Sun StorageTek Common Array Manager software and installation process. Chapter 2 describes how to install the Common Array Manager software and the local and remote host …Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Dell OpenManage Array Manager, v.3.6.0.568.5, A05. Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to configure and manage local and remote storage attached to a server, while the server is online and continuing to process requests. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Sun StorageTek Common Array Manager Software Installation Guide, v6.1. HTML. PDF. Sun StorageTek Common Array Manager CLI Quick Reference, v6.1. PDF. Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version 6.1.2. HTML. PDF.SANtricity or Common Array Manager report a critical fault of Host IO Card has Failed (xx.66.1150). SANtricity or Common Array Manager report a critical fault of Host IO Card is Degraded (xx.66.1300). SANtricity or Common Array Manager reports a critical fault of One or More Volumes not on their Preferred Path (xx.66.1010).1. On the local terminal, enter the following to enable display from the Common Array Manager host: $ xhost + 2. Telnet to the Common Array Manager host (where the Common Array Manager Installation CD or download file is located, and where the Common Array Manager will be installed): telnet x.x.x.x. 3. After logging in, switch user …Sun Storage Common Array Manager supports these arrays: Sun Storage 6000 array series. StorageTek 2500 array series. StorageTek FlexLine array series. Sun Storage …Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only.To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: root (or an administrative user for Windows) storage; guest; User names must be a currently defined user on the management host.Note - At the release of this document, there is currently no support for using the Common Array Manager to upgrade disk module and SAS-NEM firmware to a level that allows SAS-1 device coexistence with server modules with SAS-2 REMs.For more information on upgrading disk module and SAS-NEM firmware to a level that allows SAS-1/SAS-2 …Storage Common Array Manager 6.9.0. Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays Sun Storage 6000 Series, StorageTek 6000 Series, and FlexLine Arrays Sun Storage J4000 Series Arrays, Sun Storage F5100 Flash Array, and Sun Blade 6000 Disk Module Sun Storage 2500-M2 Arrays and StorageTek 2500 Series Arrays1 Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see the Sun Storage Common Array Manager Software Installation and Setup Guide. Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI).For the Sun Storage J4000 Array Family, refer to the Sun …Sun Storage Common Array Manager Installation and Setup Guide Administration, configuration, and monitoring Online help integrated with the software. Customer and field replacement procedures Service Advisor integrated with the software. Reference information for the CLI Sun Storage Common Array Manager CLI Guide sscsman pages9. Choose Typical to install the full management software on the data host. 10. Click next to display the Review Selections Screen. The screen should show that the software to be installed is the Full Install. The … 使用 GUI 管理阵列 《Sun Storage Common Array Manager 阵列管理指南,版本 6.9.0》 使用 sscs CLI 管理阵列 《Sun Storage Common Array Manager CLI Guide, Version 6.9.0》 故障排除信息和硬件更换过程 服务顾问,从 Sun Storage Common Array Manager GUI 启动 从固件版本 6.x 升级到 7.x “升级固件 ... 2 Sun StorageTek Common Array Manager Software 6.5.0 Release Notes • September 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM includes a distributed architecture which enables you to …Performing Connection and Administration Tasks 36 Connection Tasks 37 Managing From the Site LAN 37 Managing an Array Isolated From the LAN 38 1 Sun StorageTek Array Administration Guide • March 2007 Installing the Remote CLI Client 38 About Host Bus Adapters 39 About Multipathing 39 General Administration Tasks 40 Accessing, Adding, …Sun Storage Common Array Manager Software 6.7.0 Release Notes: PDF: Sun Storage Array Baseline Firmware: PDF: Sun Storage Common Array Manager Array Administration Guide, Version 6.7.0: PDF: Sun Storage Common Array Manager Quick Start Guide: PDF: Sun Storage Common Array Manager Installation and Setup Guide: … Ce document est destiné à vous guider dans les étapes de base de l’installation du logiciel Sun Storage Common Array Manager d’Oracle. Si vous procédez à une mise à niveau à partir d’une ancienne version ou souhaitez obtenir des informations complémentaires, consultez le Sun Storage Common Array ManagerGuide d’installation et de ... 2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local andSee your Sun StorageTek Common Array Manager Software Installation Guide (part number 820-4193) or Sun StorageTek Common Array Manager User Guide for the J4000 Array Family (part number 820-3765). 5. Log in as root (Solaris and Linux) or as a user with administrator privilege (Windows) on the management host. 6.2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS)This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forThe SAS expander on the Multi-Fabric NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which …Now there's an easy way to manage your storage environment. Oracle's Sun Storage Common Array Manager software provides a common, simple-to-use interface for your Sun Storage arrays. The software takes the complexity out of storage management, enabling you to accelerate deployment, simplify your environment, and …Sun Storage 2530-M2 Array - Version Not Applicable and later: Sun StorageTek[TM] Common Array Manager Software: Enabling Automatic Service Request Generation ... is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. Critical alarms generate a …Goal. Sun Storage Common Array Manager (CAM) has two main services: Java Web Console (JWC) and Fault Management Service (FMS). Generally starting and stopping the JWC service is done when troubleshooting login problems, making JWC configuration changes, installing a JWC patch, or installing a legacy JWC application.These release notes cover the software released on the Sun StorageTek Common Array Manager Software 6.0.0 CD. The Release Notes consist of the following sections: Features in This ReleaseThe Sun StorageTek Common Array Manager (CAM) software suite is your main tool for Sun Storage array enclosure management, monitoring, and service capabilities. The software has both a secure browser interface and a command-line interface (CLI). CAM is supported for use with Solaris, Linux and Windows platforms. Viewing Sun Storage …iv Sun StorageTek Common Array Manager CLI Guide • September 2009 Commands Used 21 Sample Data 21 Command Sequence 21 3. Monitoring and Administration Commands for All Arrays 27 add notification 27 Synopsis 27 Description 28 Options 28 Examples 29 add registeredarray 29 Synopsis 29 Description 29 Options 30 Examples 30This URL seems to be what you want: Installing the Typical Full Management Software. But having said that - you may want to look at a newer and more supported product. On Oracle Support I can not download the software without support for the Unit. They also don’t want to sell support / the software for the Unit.2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.Sun Storage Common Array Manager Software Release Notes, Release 6.9.0 Update December 2012. Review important late-breaking information about Sun Storage Common Array Manager.Array Technologies (NASDAQ: ARRY) has surpassed Wall Street projections four times, including the last quarterly EPS of 21 cents per share, 91% higher …Hi! I have Sun StorageTek 2540 FC array and CAM works very slowly - I can wait for software response even more than 2 minutes... I run this software on Windows machine with Firefox Web Browser but spe | The UNIX and Linux ForumsThis guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training forSun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Instead customers typically do remote scripting using the remote CLI …Category filter: Show All (183)Most Common (3)Technology (42)Government & Military (46)Science & Medicine (41)Business (40)Organizations (52)Slang / Jargon (5) Acronym Definition CAM Camera CAM Computer-Aided Manufacturing CAM Camshaft CAM 7 CAM Camcorder (video source) CAM Complementary and Alternative Medicine CAM Camden …Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Common Array Manager. 895784 Oct 22 2011 — edited Oct 22 2011. Hi Experts, I am Installing Common array manager software on sparc T5120, while installing sun java web console is missing some LION packages whether i go forward what will happen? any solution for this please guide me. Thanks, kk. Comments.Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. Instead customers typically do remote scripting using the remote CLI … 使用 GUI 管理阵列 《Sun Storage Common Array Manager 阵列管理指南,版本 6.9.0》 使用 sscs CLI 管理阵列 《Sun Storage Common Array Manager CLI Guide, Version 6.9.0》 故障排除信息和硬件更换过程 服务顾问,从 Sun Storage Common Array Manager GUI 启动 从固件版本 6.x 升级到 7.x “升级固件 ... Sun Storage Common Array Manager (CAM) - Version 6.0 and later Sun Storage Flexline 280 Array - Version Not Applicable and later All Platforms Goal. This article documents Sun StorageTek Flexline 280 (FLX280) Array's components firmware baseline bundled in each corresponding CAM release and patched versions.Sun Storage Common Array Manager supports these arrays: Sun Storage 6000 array series. StorageTek 2500 array series. StorageTek FlexLine array series. Sun Storage …

. Mypennymac

common array manager

Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a … Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.10 (English) l Review the latest array baseline firmware versions delivered with Oracle's Sun Storage Common Array Manager 6.10. Download. Sun Storage Common Array Manager Quick Start Guide (English) l This guide can help you with the basic steps of installing Oracle ... Sun Storage Common Array Manager (CAM) - Version 5.0 and later Information in this document applies to any platform. Purpose. This document lists the open ports required on a management host in order for Sun Storage Common Array Manager (CAM) to function properly. DetailsMar 24, 2021 · Sun Storage Common Array Manager (CAM) - Version 5.0 and later All Platforms Goal. There are several components of the Sun StorageTek[TM] Common Array Manager (CAM) software : Solaris Web Console(SWC) Browser/Remote sscs interface(BUI/CLI) Fault Management Service(FMS) Storage Lifecycle Manager(SLM) In Band Proxy for RAID devices クイックスタートガイド. このマニュアルでは、オラクルの Sun Storage Common Array Manager ソフトウェアをインストールする基本的な手順について説明します。. 以前のバージョンからアップグレードする場合、または追加情報が必要な場合は、『Sun Storage Common ... Title: Sun Storage Common Array Manager Quick Start Guide, Version 6.8.x Author: Oracle and/or its affiliates Subject: This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manage 爀 猀漀昀琀眀愀爀攀⸀ 䤀昀 礀漀甀 愀爀攀 甀瀀最爀愀搀椀渀最 昀爀漀洀 愀 瀀爀攀瘀椀漀甀猀 瘀攀爀猀椀漀渀 漀爀 渀攀攀搀 ... このドキュメントの目的は、StorageTek、Sun StorEdge、Sun StorageTekおよびSun Storage アレイのディスク障害の症状のトラブルシューティングを支援することです。. 現象. Common Array ManagerまたはSANtricityが、「 Failed Hot Spare or Unassigned Drive(ホットスペアの失敗または ... This document is designed to help clarify when a drive should be replaced, if this fault should be present on an array. Symptoms Include: SANtricity Storage Manager shows an alert for Impending Drive Failure Low Risk; Common Array Manager shows an alarm for Impending Drive Failure Risk Low (xx.66.1026) このドキュメントの目的は、StorageTek、Sun StorEdge、Sun StorageTekおよびSun Storage アレイのディスク障害の症状のトラブルシューティングを支援することです。. 現象. Common Array ManagerまたはSANtricityが、「 Failed Hot Spare or Unassigned Drive(ホットスペアの失敗または ... Look for the StorageTek Common Array Manager (CAM) Software release 6.1.2 or later. Using CAM With Disk Blades and Virtualized Multi-Fabric 10GbE NEM. CAM provides both a browser and command-line interface. When using the browser interface, you set up user accounts. When an authorized user logs in, information is laid out in pages.Sun StorageTekTM Common Array Manager CLI Quick Reference. This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems from the command-line interface (CLI). You’ll find the most current information about Sun StorageTek Common Array Manager software in these 6.1.1 version Release Notes, including features, release ... Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. This document shows how to upgrade firmware on Sun Storage 2500, 2500-M2, 6000 Arrays, J4000 JBODs, and F5100 Flash Arrays using Sun Storage Common Array Manager (CAM) within the same top level firmware (from 06.xx to 06.xx or from 07.xx to 07.xx). For information on upgrading firmware from 06.xx to 07.xx, please refer to the …This chapter describes performing general administrative tasks applicable to all arrays. It contains the following subsections: “Using the Browser Interface” on page 2 “Administering Storage Arrays” on page 11 “Administering User Accounts” on page 17. 1. Using the Browser Interface Sun StorageTek[TM] Common Array Manager (CAM)には、Sun StorEdge[TM]、Sun StorageTek [TM]、StorageTek[TM]、Sun Storage[TM]アレイのサポート・ベースの構成およびログを収集する機能があります。これはブラウザまたはCLIインタフェースを使用して実行できます。 Sun Storage Common Array Manager Array Baseline Firmware Reference, Version 6.8.1. 2 2510_exmoor N1532-735843-002 nge/N1532-735843-002.dlp .

Popular Topics